Download Print this page

Error Messages - HP Surestore 6164 - Switch Reference Manual

Hp surestore fc switch 6164 installation and reference guide
Hide thumbs Also See for Surestore 6164 - Switch:

Advertisement

Error Messages

Diagnostics
Table 9. Diagnostic Tests for the 2250 Switch (continued)
Test
Cross Port Test
Spin Silk Test
SRAM Data
Retention Test
CMem Data
Retention Test
Switch Online
The error message log can be accessed through the Telnet command
errDump. Note any messages before removing power from the switch,
because error messages are stored in RAM and are lost when power is
removed.
For a detailed description of each error message, see the Fabric OS
Reference Manual.
Command
Description
crossPortTest
Checks all switch paths. Frames
transmitted by port M are looped
back using external cable and
received at port N. Switch must
be offline.
spinSilk
Checks all switch paths at the
maximum speed of 1 Gbps.
Frames transmitted by port M
are looped back using external
cables, and when received by
port N are sent again by port M
in an external loop. Switch must
be offline.
sramRetention
Verifies that data written into
Test
ASIC memories is retained.
Switch must be offline.
CmemRetention
Verifies that data written into
Test
ASIC SRAMs is retained.
Switch must be offline.
switchEnable
Returns switch to online state.
79

Advertisement

loading

This manual is also suitable for:

Fc switch surestore 6164