HP StorageWorks 8B - FC Entry Switch Reference Manual page 314

Fabric os reference manual (version 3.0)
Hide thumbs Also See for StorageWorks 8B - FC Entry Switch:
Table of Contents

Advertisement

2
Error Messages
Table 2-4
Message
DIAG-LCMRS
Err#1F25, 1025
[centralMemoryTest,
cmemRetentionTest]
DIAG-LCMTO
Err#1F26, 1026
[centralMemoryTest,
cmemRetentionTest]
DIAG-MEMNULL
Err#0112
[ramTest]
DIAG-MEMSZ
Err#0111
[ramTest]
DIAG-MEMORY
Err#0110
[ramTest]
DIAG-NOSEGMENT
Err#3081,3881
[crossPortTest,
spinSilk]
DIAG-PORTABSENT
Err#2670, 3070, 3870
[portLoopbackTest,
crossPortTest, spinSilk]
DIAG-PORTDIED
Err#265F, 305F, 385F
[portLoopbackTest,
crossPortTest, spinSilk]
DIAG-PORTM2M
Err#3080, 3880
[crossPortTest,
spinSilk]
2-12
Diagnostic Error Messages (Continued)
Description
Central Memory Read Short: M bytes
requested but not received
Central Memory Timeout: Data transfer
initiated did not complete within the
timeout period
Test failed to malloc
Memory size to be tested is less than or
equal to zero
Data read from RAM location did not
match previously written data into same
location
Port failed to go into loopback mode
Port is not present
Port was in loopback mode and then
went inactive
Port is found to be connected to itself
(self loopback). This Port M to Port M
connection is not allowed by the test
Probable Cause
Action
ASIC failure
Replace mainboard
assembly
ASIC failure
Replace mainboard
assembly
mainboard failure
Replace mainboard
assembly
mainboard failure
Replace mainboard
assembly
CPU RAM failure
Replace mainboard
assembly or
DRAM module
Improper SFP or
Reseat SFPs and
cable connection
cables and
re-execute test
ASIC or mainboard
Replace mainboard
failure
assembly
ASIC, SFP module
Replace mainboard
or fiber cable failure
assembly, SFP
module or fiber
cable
Improper cable
Reconnect port
connection
(M) to another port
(N) and re-execute
the test
Fabric OS Reference