Resetting Bad Ports; Post Test Commands - HP StorageWorks 8B - FC Entry Switch Reference Manual

Fabric os reference manual (version 3.0)
Hide thumbs Also See for StorageWorks 8B - FC Entry Switch:
Table of Contents

Advertisement

Resetting Bad Ports

If any port fails during a diagnostic test, it is marked BAD in the status display.
To retest a port which has been marked BAD, clear the port and set to OK using the
diagClearError command. This command clears the port status only and does not clear the logs or
change the port's condition. The diagClearError command should only be used during diagnostic
procedures to reset a bad port for retest.

Post Test Commands

When the switch is booted a series of commands are executed to test the hardware of the switch.
This procedure is called the POST (power on self test).
The Fabric OS POST includes the following tests:
Table 2-1
Command
ramTest
portRegTest
centralMemoryTest
cmiTest
sramRetentionTest
turboRAMTest
camTest
statsTest
filterTest
portLoopbackTest
spinsilk
For more information about these tests, refer to the individual command descriptions in Chapter 1,
Telnet Commands.
Note:
Fabric OS Reference
Post Tests
The cold boot (power reset) runs the long ramTest while the warm boot (software reset)
runs the short ramTest.
Description
Bit write and read test of SDRAMS in the switch.
Bit write and read test of the ASIC SRAMs and registers.
Bit write and read test of the ASIC central memory.
ASIC to ASIC connection test of the CMI bus.
Data retention test of the SRAMs in ASIC.
Functional test of RAM.
Functional test of the CAM memory.
Runs a statistics counter diagnostic test.
Functional test of filter configuration.
Functional test of switch by sending and receiving frames
from the same port.
Functional test of port to port path at maximum switch
speed.
2
Error Messages
2-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fabric osStorageworks fc entry switch 8b

Table of Contents