Table 2-4
Message
DIAG-PORTSTOPPED
Err#3874
[spinSilk]
DIAG-PORTWRONG
Err#3078
[crossPortTest]
DIAG-POST_SKIPPED
Err# 0004
[switch initialization]
DIAG-REGERR
Err#0B15, 0415
[portRegTest,
sramRetentionTest]
DIAG-REGERR_UNRST
Err#0B16, 0416
[portRegTest,
sramRetentionTest]
DIAG-STATS
Err#2660-2662, 3060 - 3062
[portLoopback Test,
crossPortTest]
DIAG-TIMEOUT
Err#266F, 306F, 386F
[portLoopbackTest,
crossPortTest,
centralMemoryTest]
DIAG-XMIT
Err#2271, 2671, 3071, 3871
[portLoopbackTest,
crossPortTest, spinSilk,
camTest]
Fabric OS Reference
Diagnostic Error Messages (Continued)
Description
Port is no longer transmitting, as
indicated by the Number Of Frames
Transmitted counter being stuck at N
frames
Frame erroneously received by port M
instead of the intended port N
POST is skipped
Data read from ASIC register or ASIC
SRAM did not match data previously
written into same location
Port failed to unreset
Port counter value did not match the
number of frames actually transmitted.
Possible counters reporting:
•
FramesTx - number of frames
transmitted
•
FramesRx - number of frames
received
•
Cl3FrmRx - number of Class 3
frames received
For portLoopbackTest and crossPortTest:
•
Port failed to receive frame within
timeout period
•
For centralMemoryTest
•
Port failed to detect an interrupt
within the timeout period
Port failed to transmit frame
Error Messages
Probable Cause
Action
ASIC, GBIC module
Replace mainboard
or fiber cable failure
assembly, GBIC
module or fiber
cable
ASIC failure
Replace mainboard
assembly
Informational Only
None required
ASIC failure
Replace mainboard
assembly
ASIC failure
Replace mainboard
assembly
ASIC, GBIC module
Replace mainboard
or fiber cable failure
assembly, GBIC
module or fiber
cable
ASIC, SFP module
Replace mainboard
or fiber cable failure
assembly, SFP
module or fiber
cable
ASIC failure
Replace mainboard
assembly
2
2-13