HP StorageWorks 8B - FC Entry Switch Reference Manual page 137

Fabric os reference manual (version 3.0)
Hide thumbs Also See for StorageWorks 8B - FC Entry Switch:
Table of Contents

Advertisement

Examples
To display the Link State Record for the local switch, as indicated by self keyword (the local
switch has four links in NB_ST_FULL state, three of them connected to switch 5, and one
connected to switch 4.
switch:admin> lsdbshow
Domain = 7 (self), Link State Database Entry pointer = 0x103946a0
lsrP
earlyAccLSRs = 1
ignoredLSRs
lastIgnored
installTime
lseFlags
uOutIfs
uPathCost
uOldHopCount
uHopsFromRoot = 0
mOutIfs
parent
mPathCost
mHopsFromRoot = 2
Link State Record:
Link State Record pointer = 0x1035bb30
lsAge
reserved
type
options
lsId
advertiser
incarn
length
chksum
linkCnt = 4, flags = 0x0
LinkId = 4, out port = 3, rem port = 2, cost = 1000, costCnt = 0, type = 1
LinkId = 5, out port = 5, rem port = 5, cost = 1000, costCnt = 0, type = 1
LinkId = 5, out port = 6, rem port = 3, cost = 1000, costCnt = 0, type = 1
LinkId = 5, out port = 7, rem port = 4, cost = 1000, costCnt = 0, type = 1
See Also
interfaceShow
nbrStateShow
Fabric OS Reference
= 0x1035bb30
= 0
= Never
= 0x4f20a (324106)
= 0xa
= 0x0
= 0
= -1161889074
= 0x20
= 0x4
= 2000
= 138
= 0
= 1
= 0x0
= 7
= 7
= 0x80000217
= 92
= 0x2fdd
1
Telnet Commands
1-123