Fwalarmsfilterset - HP StorageWorks 8B - FC Entry Switch Reference Manual

Fabric os reference manual (version 3.0)
Hide thumbs Also See for StorageWorks 8B - FC Entry Switch:
Table of Contents

Advertisement

fwAlarmsFilterSet

This command determines whether alarms are enabled for Fabric Watch.
Synopsis
fwAlarmsFilterSet [0|1]
Availability
admin
Description
Use this command to configure alarm filtering for Fabric Watch. By turning off the alarms, all
non-environment class alarms are suppressed. By turning on the alarms, all class alarms are
generated.
Note:
Operands
This command has the following operand:
0 | 1
Example
To enable alarms in Fabric Watch:
See Also
fwAlarmsFilterShow
Fabric OS Reference
This command requires a Fabric Watch License.
Specify 1 for enabling the alarms, 0 for disabling the alarms. The default value is
0 (alarms are deactivated). This operand is optional.
switch:admin> fwAlarmsFilterSet
Committing configuration...done.
FW: Alarms are disabled
switch:admin> fwAlarmsFilterSet 1
Committing configuration...done.
FW: Alarms are enabled
1