camTest

Test the functionality of Content Addressable Memory (CAM).
Synopsis
camTest [passCount]
Availability
admin
Description
Use this command to verify that Content Addressable Memory (CAM) is functionally correct. The
CAM is used by QuickLoop to translate the SID.
Note:
Operands
This command has the following operand:
passCount
Example
To verify that Content Addressable Memory (CAM) is functioning correctly:
Errors
Below are possible error messages if failures are detected:
DIAG-CAMINIT
DIAG-XMIT
DIAG-CAMSID
See Also
ramTest
portRegTest
centralMemoryTest
cmiTest
sramRetentionTest
turboRamTest
statsTest
filterTest
portLoopbackTest
spinSilk
Fabric OS Reference
This command may not be executed on an enabled switch. You must first disable the switch
using the switchDisable command.
Specify the number of times to execute this test. The default value is 1. This
operand is optional.
switch:admin> camTest 2
Running CAM Test .............. passed.