Isltopocheck - HP StorageWorks 8B - FC Entry Switch Reference Manual

Fabric os reference manual (version 3.0)
Hide thumbs Also See for StorageWorks 8B - FC Entry Switch:
Table of Contents

Advertisement

islTopoCheck

Display ISL sgroup connections for a switch.
Synopsis
islTopoCheck
Availability
admin
Description
This command displays the ISL sgroup connections and status for this switch. This command is
used to verify that the switch is properly cabled and configured. A switch with properly configured
ISL connections reports a status of OK for each of these ports.
Note:
Operands
None.
Example
The following example displays islTopoCheck on a misconfigured FC 6164 switch. In a proper
configuration, all of the switches would have valid domains and valid names and each of the ports
status would be OK.
switch:admin> islTopoCheck
ISL data for type: S32_6_1, sgroup: My_group
idx
domain
01
01
02
02
03
-01
04
-01
05
-01
06
-01
Domain: 2, wwn: 10:00:00:60:69:10:a0:4e
isl port
expected switch
0
08 -> jr_1003
1
09 -> jr_1003
2
10 -> jr_1003
3
11 -> jr_1003
4
12 -> -UNKNOWN-
5
13 -> -UNKNOWN-
6
14 -> -UNKNOWN-
7
15 -> -UNKNOWN-
See Also
islTopoShow
Fabric OS Reference
This command is used for the FC 6164 only.
expected wwn
10:00:00:60:69:20:02:9f
10:00:00:60:69:10:a0:4e
00:00:00:00:00:00:00:03
00:00:00:00:00:00:00:04
00:00:00:00:00:00:00:05
00:00:00:00:00:00:00:06
port
: 00
: 01
: 02
: 03
: 12
: 13
: 14
: 15
name
jr_1003
switch
-UNKNOWN-
-UNKNOWN-
-UNKNOWN-
-UNKNOWN-
actual switch
port
jr_1003
: 00
jr_1003
: 01
jr_1003
: 03
-UNKNOWN-
:-01
-UNKNOWN-
:-01
jr_1003
: 07
-UNKNOWN-
:-01
-UNKNOWN-
:-01
1
Telnet Commands
status
OK
OK
Wrong port
Bad status
Bad status
Wrong switch
Bad status
Bad status
1-111

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fabric osStorageworks fc entry switch 8b

Table of Contents