HP StorageWorks 8B - FC Entry Switch Reference Manual page 163

Fabric os reference manual (version 3.0)
Hide thumbs Also See for StorageWorks 8B - FC Entry Switch:
Table of Contents

Advertisement

alias
Example
To add a filter based monitor for all Extended Link Service request (R_CTL=0x22 and
TYPE=0x01) to port 2:
As a special case, to add a filter based monitor for SOFi3 on port 2:
See Also
perfAddEEMonitor
perfAddIPMonitor
perfAddReadMonitor
perfAddRWMonitor
perfAddSCSIMonitor
perfAddWriteMonitor
Fabric OS Reference
SOFx frames are considered a special case. The Offset is specified as 0x0,
valueList are specified with:
0 - SOFf
1 - SOFc1
2 - SOFi1
3 - SOFn1
4 - SOFi2
5 - SOFn2
6 - SOFi3
7 - SOFn3
Specify a name for this monitor. This character string can be a maximum of 10
characters long and is truncated if more characters are specified. This operand
must be enclosed in quotation marks. This operand is optional.
switch:admin> perfAddUserMonitor 2, "4, 0xff, 0x22; 12, 0xff, 0x01"
User monitor #0
successfully added
switch:admin>
switch:admin> perfAddUserMonitor 2, "0, 0xff, 6"
User monitor #1 successfully added
switch:admin>