msTDDisable

Disable the Management Server Topology Discovery Management service.
Synopsis
msTdDisable ["ALL"]
Availability
admin
Description
Use this command to disable the Management Server Topology Discovery Management Service
locally or fabric-wide. This command will disable the Topology Discovery Management Service of
the local switch and commit the changes to flash memory of the local switch. If the optional
parameter "ALL" is given, then the command is executed on the entire fabric.
Once disabled, even in the event of a power boundary, the switch will be boot up with the
Management Server Topology Discovery Management Service DISABLED.
Note:
Operands
This command has the following operand:
ALL
Example
To disable the Management Server Topology Discovery service locally or fabric-wide:
switch:admin> msTdDisable
This will erase all NID entries. Are you sure?
Committing configuration...done.
switch:admin> msTdDisable "ALL"
This will erase all NID entries. Are you sure?
Committing configuration...done.
See Also
msTdEnable
Fabric OS Reference
Topology Discovery Management requires the attached devices which include attached
switches to support the RNID ELS command.
Specify ALL to disable the Topology Discovery Management function on all
switch's in the fabric. The operand ALL must be enclosed in quotation marks
and must be in capital letters. This operand is optional.
Telnet Commands
(yes, y, no, n): [no] y
(yes, y, no, n): [no] y
1
1-133

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the StorageWorks 8B - FC Entry Switch and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Fabric osStorageworks fc entry switch 8b

Table of Contents