perfAddReadMonitor

Add a filter-based monitor for the SCSI Read command.
Synopsis
perfAddReadMonitor port[, "alias"]
Availability
admin
Description
Use this command to define filter-based monitors to count the number of SCSI FCP Read
commands in Fibre Channel frames.
After a successful execution of this command, a monitor number is displayed. The monitor number
is provided for easy manipulation of these filter-based performance monitors. The optional user
defined alias is also displayed if one was specified. All valid monitor numbers and user-defined
aliases can be retrieved with the perfShowFilterMonitor command.
The maximum number of filters is 8 per port including user-defined filters, read filters, write filters,
and read/write filters.
Operands
This command has the following operands:
port
alias
Example
To add a SCSI Read monitor to port 2:
See Also
perfAddEEMonitor
perfAddIPMonitor
perfAddRWMonitor
perfAddSCSIMonitor
perfAddUserMonitor
perfAddWriteMonitor
Fabric OS Reference
Specify the port number where you want to add a SCSI Read frame monitor. This
operand is required.
Specify a name for this monitor. This character string can be a maximum of 10
characters long and is truncated if more characters are specified. This operand
must be enclosed in quotation marks. This operand is optional. The default alias
is SCSI_RD.
switch:admin> perfAddReadMonitor 2
SCSI Read filter monitor #2 added
switch:admin>