Portcfgspeed - HP StorageWorks 8B - FC Entry Switch Reference Manual

Fabric os reference manual (version 3.0)
Hide thumbs Also See for StorageWorks 8B - FC Entry Switch:
Table of Contents

Advertisement

1
Telnet Commands

portCfgSpeed

Configure the port speed level.
Synopsis
portCfgSpeed port[, speed_level]
Availability
admin
Description
Use this command to configure the speed of a port to a particular level. After this command is
issued, the port is disabled and enabled so that the port comes up with the new speed setting. The
configuration is saved in the non-volatile memory and is persistent across switch reboot or power
cycle.
If the command is specified without an operand, you are prompted to enter the speed value.
The output of the portShow command displays the current achieved speed of a port and the
portCfgShow command displays the user desired speed setting for a port.
Operands
This command has the following operands:
port
speed_level Specify the speed of a port. This operand is optional. Valid values are one of the
Example
To configure the speed of port 3 to 2 Gbps:
See Also
switchCfgSpeed
portShow
1-176
Specify the port number where you want to set the speed. This operand is
required.
following:
0
Auto-sensing mode. The port automatically configures for the highest speed.
1
1 Gbps mode. The port will be at fixed speed of 1 Gbps.
2
2 Gbps mode. The port will be at fixed speed of 2 Gbps.
switch:admin> portCfgSpeed 1
Please enter the TX & RX speed level -- : (0..2) [0] 2
Committing configuration...done.