switchStatusShow

Displays the overall status of the switch.
Synopsis
switchStatusShow
Availability
All Users
Description
Use this command to display the overall status of the switch. The overall status is calculated based
on the most severe status of all contributors:
Internal Switch Status
Faulty Ports
Missing GBICs
Power Supplies
Fans
Temperatures
Port Status
The overall status can be one of the following:
Healthy/OK - every contributor is healthy
Marginal/Warning - one or more components are causing a warning status
Down/Failed - one or more contributors have failed
If the overall status is not HEALTHY/OK, the contributing factors are listed.
Operands
None.
Example
There are two examples below. The first shows a switch with a status of MARGINAL, the second
shows the same switch after all the errors have been fixed.
See Also
switchStatusPolicyShow
switchStatusPolicySet
Fabric OS Reference
switch:admin> switchStatusShow
The overall switch status is Marginal/Warning
Contributing factors:
*
1 missing power supply triggered the Marginal/Warning status
*
2 bad fans, 4 good fans triggered the Marginal/Warning status
*
1 missing GBIC triggered the Marginal/Warning status
switch:admin> switchStatusShow
The overall switch status is HEALTHY/OK