Warning And Error Messages - HP Surestore 64 - Director Switch User Manual

Fw 05.01.00 and sw 07.01.00 - director product manager - user guide
Hide thumbs Also See for Surestore 64 - Director Switch:
Table of Contents

Advertisement

Configuring the Director
Note:
data speeds.

Warning and Error Messages

When you click Activate, if any node attached to a port does not match the WWN
or nickname in that port's Bound WWN column, a warning dialog box displays,
as shown in
off, and the ports will attach to the respective devices identified in the Bound
WWN column.
130
When you change a port's speed and click Activate on the dialog box, a
confirmation message displays stating that this setting will temporarily
disrupt port data transfers.
Your director model, firmware, and port cards may not allow 2 Gb/sec
Bound WWN—Enter the WWN or nickname of the device that is attached to
the port.
If the check box in the Port Binding column is checked and a WWN is
entered in the Bound WWN field, only the specified device can attach to the
port.
If the check box in the Port Binding column is checked but no WWN is
entered in the Bound WWN field, no device can connect to the port.
If the check box in the Port Binding column is not checked, any device can
connect to the port (provided that the port type matches and the check box in
the Blocked column is not checked). Any WWN or nickname entered in the
Bound WWN field is stored.
When you click Activate, if the check box in the Port Binding column is
checked and the WWN or nickname in the Port Binding column does not
match the device actually connected to the port, the warning dialog box
displays. If you click Continue, the currently attached devices are logged off.
Figure
35. If you click Continue, all the nodes listed will be logged
Director Product Manager User Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

Director 2/64Director 2/140

Table of Contents