Fabric Watch Error Messages

Below are six sample Fabric Watch error messages. The threshold name in the first error message is
fopportState003. The threshold label in the first error message is (FOP Port State Changes 3).
0x1003f2d0 (tThad): May 22 19:20:23
Error FW-BELOW, 3, fopportState003 (FOP Port State Changes 3) is below low boundary. current value : 0
Change(s)/minute. (normal)
0x1003f2d0 (tThad): May 22 19:13:57
Error FW-ABOVE, 3, fopportCRCs007 (FOP Port Invalid CRCs 7) is above high boundary. current value : 5
Error(s)/minute. (faulty)
0x1003f2d0 (tThad): May 22 17:31:33
Error FW-ABOVE, 3, fopportSync003 (FOP Port Loss of Sync 3) is above high boundary. current value : 3
Error(s)/minute. (faulty)
0x1003f2d0 (tThad): May 22 17:31:33
Error FW-ABOVE, 3, fopportLink003 (FOP Port Link Failures 3) is above high boundary. current value : 1
Error(s)/minute. (faulty)
0x1003f2d0 (tThad): May 22 17:31:33
Error FW-CHANGED, 4, fabricFL000 (Fabric Fabric login) value has changed. current value : 23 Login(s). (info)
0x1003f2d0 (tThad): May 22 17:17:33
Error FW-ABOVE, 3, alpaPerfCRC004 (ALPA Invalid CRCs 4) is above high boundary. current value : 10
Error(s)/minute. (faulty)
The Threshold name of the error message is equal to the class name, area name, and element index
added together to form a single character string.
For example:
class name = env,
area name = Fan,
element index = 000-002,
then the threshold name is envFan000 - envFan002
Another example is as follows:
class name = gbic,
area name = Temp,
element index = 001-00x,
then the threshold name is gbicTemp001-gbicTemp00x