Orientalmotor AZX Series Operating Manual page 92

Motorized actuator equipped
Hide thumbs Also See for AZX Series:
Table of Contents

Advertisement

Macro operation
„ Timing chart
1. Turn the S-ON input ON.
2. Check the READY output is being ON.
3. Turn the FW-JOG-C input (or RV-JOG-C input) ON.
The READY output is turned OFF, the MOVE output is turned ON, and the motor starts inching operation.
4. The motor starts JOG operation when the time set in the "JOG-C time from JOG-P to JOG" parameter has passed.
5. The motor starts high-speed JOG operation when the time set in the "JOG-C time from JOG to JOG-H" parameter
has passed.
6. Turn the FW-JOG-C input (or RV-JOG-C input) OFF.
The motor starts deceleration stop.
7. When the motor stops, the READY output is turned ON and the MOVE output is turned OFF.
FW-JOG-C input
(RV-JOG-C input)
S-ON input
READY output
MOVE output
Internal speed command
FW-JOG-C input
(RV-JOG-C input)
S-ON input
READY output
MOVE output
Internal speed command
*1 It is set with the "JOG-C time from JOG-P to JOG" parameter.
*2 It is set with the "JOG-C time from JOG to JOG-H" parameter.
92
ON
3
OFF
ON
1
OFF
2
ON
OFF
ON
OFF
ON
OFF
ON
OFF
60 ms or less
5 ms or less
ON
OFF
5 ms or less
ON
OFF
5
4
2 ms or less
*1
*2
6
7
2 ms or less
2 ms or less