Orientalmotor AZX Series Operating Manual page 29

Motorized actuator equipped
Hide thumbs Also See for AZX Series:
Table of Contents

Advertisement

MEXE02
Name
code
Next data number
Area offset
Area width
p1
Loop count
Loop offset
Loop end number
(Low) I/O event
number
(High) I/O event
number
*1 A value in the brackets [ ] is shown on the screen of the MEXE02 software.
*2 The setting unit is followed the "Acceleration/deceleration unit" parameter.
Description
Sets the next data number.
Sets the distance from the center position
of the range in which the MAREA output is
turned ON to the target position of
positioning operation.
Sets the distance to the operation starting
position in the case of continuous
operation.
Sets the range in which the MAREA output
is turned ON.
Sets the number of loop times.
Offsets the position (travel amount) every
time loop is executed.
Sets to the operation data number in which
loop is completed.
Sets the number of the operation I/O event
to generate a low event. The condition to
generate the event is set in the operation I/
O event.
Sets the number of the operation I/O event
to generate a high event. If a low event and
a high event are generated at the same
time, the high event is prioritized. The
condition to generate the event is set in
the operation I/O event.
Stored data (SD) operation
Setting range*1
−256: No link [Stop]
−2: Operation data number after
next one [ ↓↓ (+2)]
−1: Next operation data number
[ ↓ (+1)]
0 to 255: Operation data number
−2,147,483,648 to
2,147,483,647 steps
−1: Disable
0 to 4,194,303 steps
0: No loop [−]
2 to 255: Number of loop times
[loop 2{ to loop 255{]
−4,194,304 to 4,194,303 steps
0: Not the loop end point [−]
1: Loop end point [}L-End]
−1: Disable [−]
0 to 31: Operation I/O event
number
Initial value
−1
0
−1
0
0
0
−1
29