„ Absolute positioning
Set the target position on coordinates with the home as a reference.
z Example:
When the motor is operated from the command position 100 to the target position 8,600
Setting the operation data
Operation type
Absolute positioning
Operation example
Speed
2,000
500
0
100
Operating method
1. Turn the S-ON input ON.
2. Check the READY output is being ON.
3. Select the operation data number using the M0 to M7 inputs, and turn the START input ON.
4. The READY output is turned OFF, and the motor starts operation.
5. Check the READY output has been turned OFF and turn the START input OFF.
6. When the operation is completed, the READY output is turned ON.
START input
M0 to M7 inputs
S-ON input
READY output
Internal speed command
Position
Speed
Starting/changing rate
[step]
[Hz]
8,600
2,000
8,600
Position
ON
3
5
OFF
ON
OFF
ON
1
OFF
2
ON
OFF
4
Stopping deceleration
[kHz/s]
[kHz/s]
1.500
1.500
Speed
2,000
500
0
START input
Stored data (SD) operation
Time
6