Orientalmotor AZX Series Operating Manual page 265

Motorized actuator equipped
Hide thumbs Also See for AZX Series:
Table of Contents

Advertisement

„ When the motor puts into a non-excitation state if an alarm is generated
1. If an error occurs, the ALM-B output and the MOVE output are turned OFF.
At the same time, the motor stops instantaneously.
2. Remove the cause of the alarm before turning the ALM-RST input ON.
The alarm is reset, and the ALM-B output and the READY output are turned ON.
3. Check the ALM-B output has been turned ON and then turn the ALM-RST input OFF.
Alarm factor
ALM-RST input
READY output
MOVE output
ALM-B output
S-ON input
Motor excitation
Non-excitation
Electromagnetic brake
Alarm factor
ALM-RST input
READY output
MOVE output
ALM-B output
S-ON input
Motor excitation
Non-excitation
Electromagnetic brake
1
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Excitation
Hold
Release
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
220 ms or less
Excitation
60 ms or less
Hold
Release
2
Error status
0 s or more
Error status
1 s or more
2 ms or less
2 ms or less
2 ms or less
10 ms or less
Alarms
3
2 ms or more
60 ms or less
60 ms or less
265