Orientalmotor AZX Series Operating Manual page 47

Motorized actuator equipped
Hide thumbs Also See for AZX Series:
Table of Contents

Advertisement

Timing chart
1. Turn the S-ON input ON.
2. Check the READY output is being ON.
3. Select the operation data number using the M0 and M7 inputs.
4. Turn the START input ON.
The READY output is turned OFF, the SEQ-BSY output is turned ON, and the motor starts operation.
5. Check the READY output has been turned OFF and turn the START input OFF.
6. When the operation is completed, the READY output is turned ON.
7. Check the READY output has been turned ON and turn the SSTART input ON.
Operation of the operation data number linked by manual sequential is started.
8. Check the READY output has been turned OFF and turn the SSTART input OFF.
9. When all linked operations are completed, the SEQ-BSY output is turned OFF and the READY output is turned ON.
ON
START input
OFF
ON
M0 to M7 inputs
OFF
ON
SSTART input
OFF
1
ON
S-ON input
OFF
ON
READY output
OFF
ON
SEQ-BSY output
OFF
Internal speed command
4
5
3
7
2
6
Stored data (SD) operation
8
9
47