Orientalmotor AZX Series Operating Manual page 104

Motorized actuator equipped
Hide thumbs Also See for AZX Series:
Table of Contents

Advertisement

Coordinates management
z Setting example
When setting the "Initial coordinate generation & wrap range offset ratio" parameter to "50 %" and the
"Initial coordinate generation & wrap range offset value" parameter to "0 step"
Example 1: Coordinates when the wrap setting range is 1 revolution and the resolution is 1,000 P/R
MEXE02 code
p5
Coordinates example
When the parameters are set as shown in the table, the motor can be operated on coordinates in the figure.
–500
–250
Example 2: Coordinates when the wrap setting range is 1,800 revolutions and the resolution is
1,000 P/R
MEXE02 code
p5
Coordinates example
When the parameters are set as shown in the table, the motor can be operated on coordinates in the figure.
–900,000
–450,000
If the "Wrap setting" parameter or the "Initial coordinate generation & wrap setting range" parameter
is changed, the absolute position may be shifted. When the parameter is changed, perform the
position preset (P-PRESET) or return-to-home operation.
104
Name
Electronic gear A
Electronic gear B
Initial coordinate generation & wrap coordinate setting
Initial coordinate generation & wrap setting range
Initial coordinate generation & wrap range offset ratio
Initial coordinate generation & wrap range offset value
Wrap setting
0
250
499
Name
Electronic gear A
Electronic gear B
Initial coordinate generation & wrap coordinate setting
Initial coordinate generation & wrap setting range
Initial coordinate generation & wrap range offset ratio
Initial coordinate generation & wrap range offset value
Wrap setting
0
450,000
899,999
Setting value
1
1
Manual setting
1.0 rev
50.00 %
0 step
Enable
0
–250
250
–500
Setting value
1
1
Manual setting
1,800.0 rev
50.00 %
0 step
Enable
0
–450,000
–900,000
450,000