Orientalmotor AZX Series Operating Manual page 231

Motorized actuator equipped
Hide thumbs Also See for AZX Series:
Table of Contents

Advertisement

Parameter ID
Dec
Hex
Initial coordinate
459
01CBh
generation & wrap
range offset ratio
Initial coordinate
460
01CCh
generation & wrap
range offset value
The number of the RND-
461
01CDh
ZERO output in wrap
range
2017
07E1h
Mechanism lead
2032
07F0h
Mechanism settings
2033
07F1h
Gear ratio setting
Initial coordinate
2034
07F2h
generation & wrap
coordinate setting
Mechanism limit
2035
07F3h
parameter setting
Mechanism protection
2036
07F4h
parameter setting
JOG/HOME/ZHOME
2037
07F5h
operation setting
Mechanism lead
2553
09F9h
decimal digit setting
*1 The setting unit is followed the "Acceleration/deceleration unit" parameter.
*2 Selecting "2: Positive side = Counterclockwise (the driver parameter is applied) or "3: Positive side = Clockwise (the driver
parameter is applied)" prioritizes the fixed value of the ABZO sensor for parameters other than the "Motor rotation direction."
Name
Description
Sets the offset ratio of the wrap
range.
Sets the offset amount of the
wrap range.
Sets the number of times to
turn the RND-ZERO output ON
in the wrap range.
Sets the lead of the ball screw.
To change the mechanism
settings parameter, select
"Manual setting. "
Sets the gear ratio for geared
motor. When "0: Gear ratio
setting disable" is set, the gear
ratio is considered as "1."
To change the initial coordinate
generation & wrap coordinate
parameter, select "Manual
setting. "
Disables the ABZO setting of
the mechanism limit parameter.
Disables the ABZO setting of
the mechanism protection
parameter.
To change the parameter for
JOG operation, return-to-home
operation, and high-speed
return-to-home operation,
select "Manual setting. "
Sets the number of decimal
places when the lead of the ball
screw contains a decimal point.
Parameter R/W commands
Initial
Setting range
value
0 to 10,000 (1=0.01 %)
5,000
−536,870,912 to
536,870,911 steps
1 to 536,870,911
divisions
1 to 32,767
0: Prioritize ABZO
setting
1: Manual setting
0: Gear ratio setting
disable
1 to 32,767: Gear ratio
(1 = 0.01)
0: Prioritize ABZO
setting
1: Manual setting
0: Follow ABZO setting
1: Disable
0: Follow ABZO setting
1: Disable
0: Prioritize ABZO
setting
1: Manual setting
0: × 1 mm
1: × 0.1 mm
2: × 0.01 mm
3: × 0.001 mm
Update
C
0
C
1
C
1
C
0
D
0
C
0
D
0
D
0
D
0
D
0
C
231

Advertisement

Table of Contents
loading