Orientalmotor AZX Series Operating Manual page 215

Motorized actuator equipped
Hide thumbs Also See for AZX Series:
Table of Contents

Advertisement

Parameter ID
Dec
Hex
137
0089h
Sequence history 10
138
008Ah
Sequence history 11
139
008Bh
Sequence history 12
140
008Ch
Sequence history 13
141
008Dh
Sequence history 14
142
008Eh
Sequence history 15
143
008Fh
Sequence history 16
144
0090h
Feedback position 32-bit counter
145
0091h
Command position 32-bit counter
147
0093h
Loop count buffer
150
0096h
Settling time (ms)
160
00A0h
Main power supply count
161
00A1h
Main power supply time (min)
162
00A2h
Control power supply count
163
00A3h
Inverter voltage (1 = 0.1 V)
166
00A6h
IP ADDR SW0
167
00A7h
IP ADDR SW1
169
00A9h
Elapsed time from BOOT (ms)
184
00B8h
I/O status 1
185
00B9h
I/O status 2
186
00BAh
I/O status 3
187
00BBh
I/O status 4
188
00BCh
I/O status 5
189
00BDh
I/O status 6
190
00BEh
I/O status 7
191
00BFh
I/O status 8
1280
0500h
Alarm history details (Alarm code)
1281
0501h
Alarm history details (Sub code)
Alarm history details (Driver
1282
0502h
temperature)
Alarm history details (Motor
1283
0503h
temperature)
Alarm history details (Inverter
1284
0504h
voltage)
Alarm history details (Physical I/O
1285
0505h
input)
1286
0506h
Alarm history details (R-I/O output)
Alarm history details (Operation
1287
0507h
information 0)
Name
This indicates the history of operation data numbers executed
until now. "−1" is displayed when stopped. During operation, the
value same as the "Present operation data number" is also
displayed in the sequence history 1.
This is 32-bit counter of the feedback position. It counts
independently of the wrap function. When the control power
supply is turned on again, it returns within the wrap coordinates.
This is 32-bit counter of the command position. It counts
independently of the wrap function. When the control power
supply is turned on again, it returns to the wrap coordinates.
This indicates the present number of loop times in loop operation
(extended loop operation). The value is kept until the operation
start signal is turned ON.
This indicates the time from when the command is completed
until the IN-POS output is turned ON.
This indicates the number of times that the main power supply
was turned on.
This indicates the time elapsed since the main power supply was
turned on in minutes.
This indicates the number of times that the control power supply
was turned on.
This indicates the inverter voltage of the driver.
This indicates the input status of the IP address setting switch
(×16).
This indicates the input status of the IP address setting switch
(×1).
This indicates the time elapsed since the control power supply
was turned on.
This indicates the ON-OFF status of the internal I/O.
(Arrangement of bits
This indicates the content of the alarm history specified by the
"Alarm history details" of the maintenance command.
(Alarm history
Description
_
p.218)
_
p.255)
Monitor commands
215