Orientalmotor AZX Series Operating Manual page 212

Motorized actuator equipped
Hide thumbs Also See for AZX Series:
Table of Contents

Advertisement

Maintenance commands
„ Configuration
Configuration can be executed when all of the following conditions are satisfied.
• An alarm is not being generated.
• The motor is not operated.
• The following commands are not executed via EtherNet/IP.
− Batch data initialization
− All data batch initialization
− Read batch NV memory
− Write batch NV memory
− Read from backup
− Write to backup
• The following monitors or menus are not executed with the MEXE02 software.
− Teaching, remote operation
− I/O test
− Data writing
− Reset
The table below shows the driver status before and after Configuration is executed.
Item
PWR/ALM LED
Electromagnetic brake
Motor excitation
Output signal
Input signal
Even if monitor is executed while Configuration is being executed, the correct monitor value may not
return.
212
Configuration is ready to
execute
Green light
Hold/Release
Excitation/non-excitation
Enable
Enable
Configuration is being
After Configuration
executed
Blink in green and red
colors simultaneously
Based on the driver
Hold
Non-excitation
Disable
Disable
is executed
condition.
Enable
Enable