Orientalmotor AZX Series Operating Manual page 50

Motorized actuator equipped
Hide thumbs Also See for AZX Series:
Table of Contents

Advertisement

Stored data (SD) operation
Timing chart
1. Turn the S-ON input ON.
2. Check the READY output is being ON.
3. Select the operation data number using the M0 and M7 inputs.
4. Turn the START input ON.
The READY output is turned OFF, the SEQ-BSY output is turned ON, and the motor starts operation.
5. Check the READY output has been turned OFF and turn the START input OFF.
6. When the first operation is completed, operation linked in "Automatic sequential" is started after stop for time set
in "Drive-complete delay time."
7. When all linked operations are completed, the SEQ-BSY output is turned OFF and the READY output is turned ON.
START input
M0 to M7 inputs
S-ON input
READY output
SEQ-BSY output
Internal speed command
50
ON
3
5
OFF
ON
OFF
1
ON
OFF
2
ON
OFF
ON
4
OFF
6
7

Advertisement

Table of Contents
loading

Table of Contents