Orientalmotor AZX Series Operating Manual page 292

Motorized actuator equipped
Hide thumbs Also See for AZX Series:
Table of Contents

Advertisement

Simulating the driver operation
„ Operating procedure
This section explains how to simulate the driver operation without connecting a motor using the MEXE02 software.
1. Turn on the control power supply and the main power supply of the driver.
2. Click [Basic settings] under [Parameter] in the tree view of the MEXE02 software.
3. Set the "Driver simulation mode" parameter to "Virtual motor. "
4. Click the [Data writing] icon on the toolbar to write the data to the driver.
5. When writing is completed, turn off the control and main power supplies of the driver and on again.
6. Check if the "Driver simulation mode" parameter is updated.
Check the PWR/ALM LED of the driver repeats the following blinking.
 Green light → Red light → Green and red colors are simultaneously lit (red and green colors may overlap and it
may be visible to orange.) → No light
7. Execute positioning operation or other operation with "Teaching, remote operation" of the MEXE02 software.
Even if a motor is not connected, the command position or the feedback position will increase or decrease.
Situation for coordinates or I/O can also be checked using the I/O monitor, the status monitor, or the waveform
monitor.
8. End the driver simulation mode.
1) Click [Basic settings] under [Parameter] in the tree view.
2) Set the "Driver simulation mode" parameter to "0: Use real motor. "
3) Click the [Data writing] icon on the toolbar to write the data to the driver.
4) Turn off the control power supply and the main power supply of the driver.
292

Advertisement

Table of Contents
loading

Table of Contents