Orientalmotor AZX Series Operating Manual page 145

Motorized actuator equipped
Hide thumbs Also See for AZX Series:
Table of Contents

Advertisement

z FW-BLK input, RV-BLK input
Turning the FW-BLK input or the RV-BLK input ON causes the operation to stop according to the setting of the "FW-
BLK/RV-BLK input action" parameter. Turning the FW-BLK input ON causes the operation in the forward direction to
stop, and turning the RV-BLK input ON causes that in the reverse direction to stop. When the operation is stopped, the
remaining travel amount is cleared. While an input that have stopped the operation is being ON, the motor will not
operate even if an operation start signal to operate in the same direction as the stop signal is input. An operation start
signal in the opposite direction can be used to operate.
Related parameter
MEXE02
Name
code
FW-BLK/RV-BLK
p7
input action
The following information is generated when the FW-BLK input or the RV-BLK input is turned ON.
 When the FW-BLK input is turned ON: Forward operation prohibition
 When the RV-BLK input is turned ON: Reverse operation prohibition
When the setting of the FW-BLK/RV-BLK input action is "Deceleration stop" (when the motor stops
while the FW-BLK input is ON)
1. When the FW-BLK input is turned ON during operation in the forward direction, the motor starts the stopping
movement.
2. When the operation is stopped, the READY output is turned ON.
3. If an operation start signal in the reverse direction is input while the FW-BLK input is ON, the READY output is
turned OFF to start operation.
FW-BLK input
S-ON input
READY output
MOVE output
Internal speed command
Motor excitation
Non-excitation
Electromagnetic brake
Description
Sets how to stop the motor when the FW-BLK
input or the RV-BLK input is turned ON.
ON
1
OFF
ON
OFF
ON
OFF
ON
OFF
Excitation
Hold
Release
Setting range
0: Immediate stop
1: Deceleration stop
2
3
Input signals
Initial
value
1
145