Orientalmotor AZX Series Operating Manual page 164

Motorized actuator equipped
Hide thumbs Also See for AZX Series:
Table of Contents

Advertisement

Output signals
z AREA0 to AREA7 outputs
The AREA outputs are turned ON when the motor is inside the set area.
They are turned ON when the motor is inside the area even if the motor stops.
Related parameters
MEXE02
code
AREA0 positive direction
AREA7 positive direction
AREA0 negative direction
position/ detection range
AREA7 negative direction
p7
position/ detection range
AREA0 range setting mode
AREA7 range setting mode
AREA0 positioning standard
AREA7 positioning standard
When the "AREA range setting mode" parameter is "Range setting with absolute value"
• When a value in the "AREA positive direction position/ offset" parameter is larger than that in the "AREA negative
direction position/ detection range" parameter
When the motor position is equal to or larger than a value in the "AREA negative direction position/ detection
range" parameter or equal to or smaller than that in the "AREA positive direction position/ offset" parameter, the
AREA output is turned ON.
AREA output
• When a value in the "AREA positive direction position/ offset" parameter is smaller than that in the "AREA negative
direction position/ detection range" parameter
When the motor position is equal to or smaller than a value in the "AREA positive direction position/ offset"
parameter or equal to or larger than that in the "AREA negative direction position/ detection range" parameter, the
AREA output is turned ON.
AREA output
• When a value in the "AREA positive direction position/ offset" parameter is equal to that in the "AREA negative
direction position/ detection range" parameter
When the motor position is equal to values in the "AREA negative direction position/ detection range" parameter
and the "AREA positive direction position/ offset" parameter, the AREA output is turned ON.
AREA output
164
Name
Sets the positive direction
position/ offset
position or offset from the
to
target position for the AREA
output.
position/ offset
Sets the negative direction
position or distance from the
to
offset position for the AREA
output.
Sets the range setting mode for
to
the AREA output.
Sets the judgment criterion of
to
the position for AREA output.
ON
OFF
AREA negative
AREA positive
direction position
direction position
ON
OFF
AREA positive
AREA negative
direction position
direction position
ON
OFF
AREA positive direction position
AREA negative direction position
Description
−2,147,483,648 to
2,147,483,647 steps
0: Range setting with
absolute value
1: Offset/width setting
from the target position
0: Based on feedback
position
1: Based on command
position
Initial
Setting range
value
0
0
0
0

Advertisement

Table of Contents
loading

Table of Contents