Overview of I/O signals
z Virtual input 1 shot signal mode
MEXE02 code
p11
„ Direct output
z (Normal) Output function
MEXE02 code
p9
z Inverting mode
MEXE02 code
p9
z OFF delay time
MEXE02 code
p9
Internal signal
Direct output (DOUT)
120
Name
Virtual input (VIR-IN0)
1 shot signal mode
Virtual input (VIR-IN1)
1 shot signal mode
Enables the 1-shot signal
function of VIR-IN.
Virtual input (VIR-IN2)
1 shot signal mode
Virtual input (VIR-IN3)
1 shot signal mode
Name
DOUT0 (Normal)
output function
DOUT1 (Normal)
output function
DOUT2 (Normal)
output function
Selects an output signal to be
assigned to DOUT.
DOUT3 (Normal)
output function
DOUT4 (Normal)
output function
DOUT5 (Normal)
output function
Name
DOUT0 inverting mode
DOUT1 inverting mode
DOUT2 inverting mode
Changes ON-OFF setting of DOUT.
DOUT3 inverting mode
DOUT4 inverting mode
DOUT5 inverting mode
Name
DOUT0 OFF delay time
DOUT1 OFF delay time
DOUT2 OFF delay time
Sets the OFF delay time of DOUT.
DOUT3 OFF delay time
DOUT4 OFF delay time
DOUT5 OFF delay time
OFF delay time
ON
OFF
ON
OFF
Description
0: 1-shot signal
function is disabled
1: 1-shot signal function
is enabled
Description
Setting range
Output signals list
_
p.125
Description
Description
Setting range
Initial value
0
0
0
0
Initial value
144: HOME-END
138: IN-POS
0: No function
132: READY
134: MOVE
130: ALM-B
Setting range
Initial value
0
0
0
0: Non invert
1: Invert
0
0
0
Setting range
Initial value
0
0
0
0 to 250 ms
0
0
0