z SPD-LMT input
Turning the SPD-LMT input ON causes the operating speed to limit.
Related parameters
MEXE02
Name
code
SPD-LMT speed limit type
selection
SPD-LMT speed limit ratio
p7
SPD-LMT speed limit value
Description
Selects the setting method of the speed
limit value.
Sets the percentage of the speed limit
based on "Speed" of the operation data
being 100 %. This is enabled when the
"SPD-LMT speed limit type selection"
parameter is set to "0: Ratio."
Sets the speed limit value as "Value." This is
enabled when the "SPD-LMT speed limit
type selection" parameter is set to "1:
Value."
Input signals
Initial
Setting range
value
0: Ratio
0
1: Value
1 to 100 %
50
1 to 4,000,000 Hz
1,000