When the "AREA range setting mode" parameter is "1: Offset/width setting from the target position"
Motor operation
ON
AREA output
OFF
z FW-SLS output, RV-SLS output
When the command position is exceeded the range set in the "Software limit" parameter when the "Software
overtravel" parameter is set to other than "−1 Disable," the FW-SLS output or the RV-SLS output is turned ON.
z RND-OVF output
ON-OFF of the RND-OVF output is inverted when the wrap range is exceeded.
„ Position monitor function
Refer to "Pulse request function" on p.111 for details about the position monitor function.
z MON-OUT output
This is a signal used for I/O position output function. Coordinate information or alarm information is output.
z PLS-OUTR output
This signal is turned ON when the pulse request function is ready, and the PLS-OUTR output is turned OFF when the
output of coordinate information by pulse is completed.
„ Coordinate status indication
z ELPRST-MON output
The ELPRST-MON output is turned ON when the electrical home coordinates are enabled.
z ABSPEN output
The ABSPEN output is turned ON when the coordinates are set.
z PRST-DIS output
The PRST-DIS output is turned ON when the home is required to set again.
If the "Preset position" parameter is set to other than "0," the PRST-DIS output is turned ON when the resolution is
changed after the position preset or return-to-home operation is performed.
When the PRST-DIS output has been turned ON, perform the position preset or return-to-home operation to set the
home.
If the resolution is changed in a state where the "Preset position" parameter is set to "0," coordinates
are automatically set again. Therefore, the PRST-DIS output is not turned ON even if the resolution is
changed.
z PRST-STLD output
The PRST-STLD output is turned ON when the position preset is performed and the home information is stored in the
ABZO sensor.
z ORGN-STLD output
Products such as motorized actuators whose home is set at the time of factory shipment are delivered in a state where
the ORGN-STLD output is ON.
O set
Width
Width
Output signals
165