Orientalmotor AZX Series Operating Manual page 162

Motorized actuator equipped
Hide thumbs Also See for AZX Series:
Table of Contents

Advertisement

Output signals
„ Motor position indication
These signals are output according to the motor position.
z ZSG output
This signal is turned ON every time the feedback position of the motor increases by one round from the position
having preset by "ZSG preset" of the MEXE02 software or the maintenance command "ZSG-PRESET" of EtherNet/IP.
Related parameter
MEXE02
code
p7
ZSG signal width
Set the "ZSG signal width" parameter according to the operating speed so that the ZSG output is
output at least 1 ms.
z RND-ZERO output
If the position set with the "RND-ZERO signal source" parameter is in the home of the wrap range when the "Wrap
setting" parameter is set to "1: Enable," the RND-ZERO output is turned ON.
Using the "The number of the RND-ZERO output in wrap range" parameter can output the signal for each interval by
equally dividing the wrap range by a desired number of divisions.
Related parameters
MEXE02
code
The number of the RND-
p5
ZERO output in wrap
range
RND-ZERO signal width
p7
RND-ZERO signal source
RND-ZERO signal width is 1
RND-ZERO signal width is 2 or 3
RND-ZERO signal width is 4 or 5
RND-ZERO signal width is 10,000
162
Name
Sets the output range of the ZSG output.
Name
Sets the number of times to turn
the RND-ZERO output ON in the
wrap range.
Sets the output width of the
RND-ZERO output.
Sets the criterion of the RND-ZERO
output.
ON
OFF
ON
OFF
ON
OFF
ON
OFF
–5,000
Description
Description
1 to 536,870,911 divisions
1 to 10,000 steps
0: Based on feedback
position
1: Based on command
position
0
–1
1
–2
2
···
Initial
Setting range
value
1 to 1,800 (1 = 0.1°)
18
Initial
Setting range
value
5,000
1
10
0

Advertisement

Table of Contents
loading

Table of Contents