Orientalmotor AZX Series Operating Manual page 263

Motorized actuator equipped
Hide thumbs Also See for AZX Series:
Table of Contents

Advertisement

Related parameters
MEXE02
Name
code
Excessive position deviation
alarm
p6
Network bus error alarm
„ Characteristics of overload alarm
The time when the overload alarm is detected varies depending on the load factor.
Load factor (%)
Overload alarm detection time
100
125
150
250
300
375
Sets the condition in which the excessive
position deviation alarm is generated.
Sets the function of the network bus error
alarm.
• Overload alarm detection time (reference)
Not detected
About 10 s
About 4 s
About 1 s
About 0.5 s
About 0.3 s
* This indicates the motor output power presently generated
Description
10
9
8
7
6
5
4
3
2
1
0
100
150
200
Load factor (%)*
as a percentage of the maximum output power in the
continuous duty region.
Alarms
Initial
Setting range
value
1 to 30,000
300
(1=0.01 rev)
0: Disable
1
1: Enable
250
300
350 375
263