Monitor commands
Parameter ID
Dec
Hex
111
006Fh
Target position
112
0070h
Next number
113
0071h
Loop origin number
114
0072h
Loop count
Event monitor command position
115
0073h
(NEXT)
Event monitor feedback position
116
0074h
(NEXT)
Event monitor command position
117
0075h
(JUMP0 − Low event)
Event monitor feedback position
118
0076h
(JUMP0 − Low event)
Event monitor command position
119
0077h
(JUMP1 − High event)
Event monitor feedback position
120
0078h
(JUMP1 − High event)
Event monitor command position
121
0079h
(Operation stop)
Event monitor feedback position
122
007Ah
(Operation stop)
123
007Bh
Information
124
007Ch
Driver temperature
125
007Dh
Motor temperature
126
007Eh
Odometer (1 = 0.1 kRev)
127
007Fh
Tripmeter (1 = 0.1 kRev)
128
0080h
Sequence history 1
129
0081h
Sequence history 2
130
0082h
Sequence history 3
131
0083h
Sequence history 4
132
0084h
Sequence history 5
133
0085h
Sequence history 6
134
0086h
Sequence history 7
135
0087h
Sequence history 8
136
0088h
Sequence history 9
214
Name
• This indicates the target command position in operations shown
below as absolute coordinates.
Positioning SD operation, inching operation, high-speed return-
to-home operation, return-to-home operation (during offset
movement), positioning direct data operation
• This indicates the operation starting position in operations
shown below.
Continuous SD operation, continuous macro operation, JOG
macro operation other than inching operation, return-to-home
operation (when sensors are used), continuous direct data
operation
This indicates the operation data number specified in "Next data
number" of the operation data in operation.
The value is latched even after the operation is completed. When
"Link" is set to "No Link" or "Next data number" is set to "Stop, " "−1"
is displayed.
This indicates the operation data number that is the starting point
of the loop in loop operation (extended loop operation). When
loop is not executed or stopped, "−1" is displayed.
This indicates the present number of loop times in loop operation
(extended loop operation). When operation other than loop is
executed or loop is stopped, 0 is displayed.
Latches the position when the latch trigger in parentheses ( ) is
generated.
The value is overwritten if the same latch trigger is generated
while latching.
When the latch is cleared, 0 is displayed.
This indicates the information code presently being generated.
This indicates the present driver temperature. (1 = 0.1 °C)
This indicates the present motor temperature. (1 = 0.1 °C)
This indicates the cumulative travel distance of the motor in
revolutions. This cannot be cleared on the customer side.
This indicates the travel distance of the motor in revolutions. This
can be cleared on the customer side.
This indicates the history of operation data numbers executed
until now. "−1" is displayed when stopped. During operation, the
value same as the "Present operation data number" is also
displayed in the sequence history 1.
Description