Orientalmotor AZX Series Operating Manual page 272

Motorized actuator equipped
Hide thumbs Also See for AZX Series:
Table of Contents

Advertisement

Information
Description
Bit output signal
Configuration
INFO-CFG
request
Reboot request
INFO-RBT
If information of "Preset request" was generated for 100 ms or more in a state where the "Information
auto clear" parameter was set to "0: Disable (not turned OFF automatically), " the preset may have
been failed. There are the following two possible reasons that the preset was failed.
 The ABZO sensor is not connected to the driver.
 The preset was executed in a state where the position deviation between the command position
and the feedback position was 1.8° or more.
272
Cause
The parameter that required executing
Configuration was changed.
The parameter that required rebooting was
changed.
Clear condition
Configuration was executed.
Reboot was executed.