Orientalmotor AZX Series Operating Manual page 31

Motorized actuator equipped
Hide thumbs Also See for AZX Series:
Table of Contents

Advertisement

z Loop count, Loop offset, Loop end number
If the loop count, the loop offset, and the loop end number are set, the loop function is enabled.
_
(
"Loop function" on p.55)
z (Low) I/O event number, (High) I/O event number
If the (Low) I/O event number and the (High) I/O event number are set, the event jump function is enabled. If a low
event and a high event are generated at the same time, the high event is prioritized.
_
(
"Event jump function" on p.59)
„ Operation I/O event
This is the operation I/O event necessary for setting the (Low) I/O event number and the (High) I/O event number.
MEXE02
Name
code
Link
Next data number
Dwell
p2
Event trigger I/O
Event trigger type
Event trigger count
* A value in the brackets [ ] is shown on the screen of the MEXE02 software.
z Link, Next data number
Set the mode for link operation and the next data number when the event trigger is detected. There are four types for
link as shown below.
Type
No link
Manual sequential
Automatic sequential
Continuous sequential
operation
Description
Sets the mode for link operation after
detecting the event trigger.
Sets the next data number.
Sets the waiting time generated after
detecting the event trigger.
Sets I/O to be used as an event
trigger.
Sets the timing to detect the event
trigger. Refer to p.60 for details.
Sets the judgment time to detect the
event trigger or the number of times
of detection.
Ignores the event.
Decelerates to stop the present operation. After that, when the time set in "Dwell" has
passed, the READY output is turned ON. If the SSTART input is turned ON, the operation
based on the operation data number set in the "Next data number" is executed.
Decelerates to stop the present operation. After that, when the time set in "Dwell" has
passed, the operation based on the operation data number set in the "Next data
number" is automatically started.
Starts operation of the operation data number set in "Next data number" without
stopping the operation.
Stored data (SD) operation
Setting range*
0: No link
1: Manual sequential
2: Automatic sequential
3: Continuous sequential operation
−256: No link [Stop]
−2: Operation data number after
next one [ ↓↓ (+2)]
−1: Next operation data number
[ ↓ (+1)]
0 to 255: Operation data number
0 to 65,535 (1 = 0.001 s)
_
Output signals list
p.250
0: No setting [non]
1: ON (calculated cumulative msec)
2: ON (msec)
3: OFF (calculated cumulative msec)
4: OFF (msec)
5: ON edge
6: OFF edge
7: ON (cumulative msec)
8: OFF (cumulative msec)
0 to 65,535 (1 = 1 ms or 1 = once)
Description
Initial value
0
−256
0
0: No function
0
0
31