Orientalmotor AZX Series Operating Manual page 146

Motorized actuator equipped
Hide thumbs Also See for AZX Series:
Table of Contents

Advertisement

Input signals
FW-BLK input
READY output
MOVE output
Internal speed command
Motor excitation
Electromagnetic brake
When the setting of the FW-BLK/RV-BLK input action is "Deceleration stop" (when the motor does not
stop while the FW-BLK input is ON)
1. When the FW-BLK input is turned ON during operation in the forward direction, the motor starts the stopping
movement.
2. Even after the FW-BLK input is turned OFF, the motor continues the deceleration operation until it stops.
When the operation is stopped, the READY output is turned ON.
FW-BLK input
READY output
Internal speed command
Motor excitation
Electromagnetic brake
146
2 ms or more
ON
OFF
ON
S-ON input
OFF
ON
OFF
ON
OFF
Excitation
Non-excitation
Hold
Release
ON
OFF
ON
S-ON input
OFF
ON
OFF
Excitation
Non-excitation
Hold
Release
2 ms or less
2 ms or less
2 ms or less
2 ms or more
2 ms or less
2 ms or less

Advertisement

Table of Contents
loading