Orientalmotor AZX Series Operating Manual page 142

Motorized actuator equipped
Hide thumbs Also See for AZX Series:
Table of Contents

Advertisement

Input signals
How to stop the motor when the STOP-SOFF input is turned ON is "Immediate stop"
1. When the STOP-SOFF input is turned ON during operation, the motor stops at the command position at the time
when the ON status of the STOP-SOFF input was detected, and puts into a non-excitation state.
2. When the STOP-SOFF input is turned OFF, the motor puts into an excitation state to turn the READY output ON.
STOP-SOFF input
READY output
Internal speed command
Motor excitation
Electromagnetic brake
* It varies depending on the driving condition.
z STOP input
Turning the STOP input ON causes the motor to stop according to the setting of the "STOP/STOP-SOFF input action"
parameter. When the operation is stopped, the remaining travel amount is cleared.
Related parameter
MEXE02
code
STOP/STOP-SOFF
p7
input action
142
ON
OFF
ON
S-ON input
OFF
ON
OFF
*
Excitation
Non-excitation
Hold
Release
Name
Description
Sets how to stop the motor when
the STOP input or the STOP-SOFF
input is turned ON.
2 ms or more
60 ms or less
220 ms or less
10 ms or less
60 ms or less
60 ms or less
0: Immediate stop for both
STOP and STOP-SOFF inputs
1: Deceleration stop for STOP
input, immediate stop for
STOP-SOFF input
2: Immediate stop for STOP
input, deceleration stop for
STOP-SOFF input
3: Deceleration stop for both
STOP and STOP-SOFF inputs
Initial
Setting range
value
3

Advertisement

Table of Contents
loading