Orientalmotor AZX Series Operating Manual page 127

Motorized actuator equipped
Hide thumbs Also See for AZX Series:
Table of Contents

Advertisement

Assignment
Signal name
number
144
HOME-END
145
ABSPEN
146
ELPRST-MON
149
PRST-DIS
150
PRST-STLD
151
ORGN-STLD
152
RND-OVF
153
FW-SLS
154
RV-SLS
155
ZSG
156
RND-ZERO
159
MAREA
160
AREA0
161
AREA1
162
AREA2
163
AREA3
164
AREA4
165
AREA5
166
AREA6
167
AREA7
168
MPS
169
MBC
170
RG
172
EDM-MON
173
HWTOIN-MON
176
MON-OUT
177
PLS-OUTR
180
USR-OUT0
181
USR-OUT1
192
TRQ-LMTD
193
SPD-LMTD
196
OPE-BSY
198
SEQ-BSY
199
DELAY-BSY
200
JUMP0-LAT
201
JUMP1-LAT
202
NEXT-LAT
204
DCMD-RDY
205
DCMD-FULL
206
OL-DTCT
207
M-CHG
Output when high-speed return-to-home operation or return-to-home operation
is completed, or position preset is executed.
Output when coordinates have been set.
Output when the electrical home coordinates are enabled.
After preset, this signal is turned ON when preset is required again before the
motor is operated.
Output when the mechanical home has been set.
Output when the mechanical home suitable to the product is set at the time of
factory shipment.
The output is inverted when the wrap range is exceeded. (Toggle action)
Output when the software limit in the forward direction is reached.
Output when the software limit in the reverse direction is reached.
Output every time the feedback position of the motor rotates by one revolution
from the position having preset.
Output if the motor is at the home of the wrap range when the "Wrap setting"
parameter is set to "1: Enable."
Output when the motor is within the area that was set to the operation data.
Output when the motor is within the area.
Output when the main power supply is in an ON state.
Output when the electromagnetic brake is in a state of releasing the motor shaft.
Output when the driver is in a regeneration state.
Output when both the HWTO1 and HWTO2 inputs are turned OFF.
Output when either the HWTO1 input or the HWTO2 input is turned OFF.
Output information corresponding to the request of the I/O position output
function.
Output when the pulse request function is ready to execute.
Output a logical product (AND) or a logical sum (OR) for two types of output
signals.
Output while the torque limiting is performed.
Output while the speed limiting is performed.
Output while internal oscillation is performed.
Output while stored data operation is performed.
Output when the driver is set in a standby state (Drive-complete delay time,
Dwell),
Output when the (Low) I/O event number trigger is detected.
Output when the (High I/O event number trigger is detected.
Output when the operation is transitioned by the NEXT input.
Output when direct data operation is ready to execute.
Output when data is being written to the buffer area of direct data operation.
Output when the output torque reaches the torque to detect the overload alarm.
The output is inverted when the operation data number is transitioned. (Toggle
action)
Function
Signals list
127