„ Virtual input
Virtual input (VIR-IN) is a method in which a signal set in virtual input is input by using output of a signal set in the
virtual input source.
No wiring is required and this function can be used together with direct I/O because of the input method using the
internal I/O. Up to four virtual inputs can be set.
Name
Virtual input function
Virtual input source selection
Virtual input inverting mode
Virtual input ON signal dead time
Virtual input 1 shot signal mode
Setting example: When the TLC output is turned ON, turn the STOP input ON to stop the motor.
If parameters are set as shown in the table, the motor stops when the output torque reaches the upper limit.
MEXE02 code
Virtual input (VIR-IN0) function
Virtual input (VIR-IN0) source selection
p11
Virtual input (VIR-IN0) inverting mode
Virtual input (VIR-IN0) ON signal dead time
Virtual input (VIR-IN0) 1 shot signal mode
Selects an input signal to be assigned to VIR-IN. When a signal of the virtual
input source is output, VIR-IN is also turned ON.
Selects an output signal to be the trigger of VIR-IN.
ON-OFF setting of the signal can be changed.
The input signal is turned ON when the time having set is exceeded.
This can be used for taking measures to eliminate noise or for adjusting the
timing between devices.
The input signal having been turned ON is automatically turned OFF after
250 μs.
Name
1-shot signal function is disabled
Overview of I/O signals
Description
Setting value
STOP
TLC
Non invert
0 ms
115