SAFETY INTERLOCK DIAGRAM

Figure 9-5:
Safety Interlock Circuit
The oven door and top cover Interlock sensor switches utilize three contactor sets; one set is
used to provide open/closed status to the MIO board CPLD. The other two sets of each sensor
switch report this status to the safety control relay.
The oven door sensor switch provides two cable connectors; P3 connector of cable 821698
interfaces switch status to the safety control relay.
The top cover sensor switch provides two cable connectors; P4 connector of cable 821698
interfaces switch status to the safety control relay.
Power (+24 VDC) to the safety control relay and dual contactors is provided by P5 of cable
821698.
Power (+48 VDC) to the dual contactors is provided by P22 of cable 821698 on the MIO board.
One contact set of each of the dual contactors utilize +24 VDC to feedback contactor status to
the safety control relay.
No calibration or periodic testing of the interlock relays is required.