The Prepare for Calibration page will be displayed
the screen, making sure to install a build sheet, and then press the Next button.
•
Within the Select Calibration Part Location page
on the build sheet and then press the Next button.
•
The Build Calibration Part screen will be displayed
building (a Z tip-to-tip calibration will not be performed).
•
Once the calibration part is complete you will be prompted to remove the part from the printer
(Figure
6-8). Remove the completed part and then press the Next button.
•
Repeat the instructions in
the calibration toolpath is centered at 0 for the X and Y axis is preferable. However, readjusting
until the calibration toolpath for X and Y is within tolerance, which is at or under 2 or 0.002 in.
(0.05 mm) for an axis, is acceptable.
E.
Proceed to the Z offset adjustment
tolerance.
9.
Determine the Z Offset Adjustment.
Note: Do not measure for Z until the calibration part shows the XY offset to be at
2 (0.05 mm) or less for the X and Y axis (see
A.
Peel the support layer from the inner square of the calibration part.
B.
Measure the thickness of the support layer on each side of the square with a caliper or
micrometer. Measure in the center of each side; measuring near the corners will result in
inaccurate values.
C.
Take the average value of the four measurements, this is the number you will enter for the Z
offset adjustment.
Figure 6-16:
Remove and Measure Support Layer
step
7. Continue to check and adjust for XY offset. Readjusting until
(step
9) once the calibration toolpath for X and Y is within
step 7
205
(Figure
6-4). Perform the steps indicated on
(Figure
6-5) select the calibration part's location
(Figure
6-7) and the calibration part will begin
for details).
Measure support layer
here (on all 4 sides)
Peel support
layer here