to remove the part from the printer (see
the Next button.
•
Repeat the instructions in
the calibration toolpath is centered at 0 for the X and Y axis is preferable. However, readjusting
until the calibration toolpath for X and Y is within tolerance, which is at or under 2 or 0.002 in.
(0.05 mm) for an axis, is acceptable.
E.
Proceed to the Z offset adjustment
within tolerance.
20.
Determine the Z Offset Adjustment.
Note: Do not measure for Z until the calibration part shows the XY offset to be at
2 (0.05 mm) for less or the X and Y axis (see
A.
Peel the support layer from the inner square of the calibration part.
B.
Measure the thickness of the support layer on each side of the square with a caliper or
micrometer. Measure in the center of each side; measuring near the corners will result in
inaccurate values.
C.
Take the average value of the four measurements; this is the number you will enter for the Z
offset adjustment.
Figure 5-15:
Remove and Measure Support Layer
step 17
step
19. Continue to check and adjust for XY offset. Readjusting until
(step
20) once the calibration toolpath for X and Y is
step 19
157
C.). Remove the completed part and then press
for details).
Peel support
layer here
Measure support layer
here (on all 4 sides)