B.
Determine where on each axis the support toolpath is most centered between the X-Y
alignment indicators (see
Figure 5-12
for Metric units). The numbers on the calibration part represent thousandths of
an inch (e.g., 4 = 0.004 in. (0.1mm)).
Figure 5-9:
Calibration Part - No Adjustment Needed (English units)
Magnified single side of a calibration part with a reading of 0.
Support
toolpath
Figure 5-10:
Calibration Part - Adjustment Needed (English units)
Support toolpath is most centered between the alignment
indicators at the 4, indicating an adjustment of +X = 0.004
Support
toolpath,
most
centered
at 4
Figure 5-9
and
Figure 5-10
Most
centered
at 0
Alignment
indicators
Not
centered
at 0
Alignment
indicators