Use the Up button to enter the value obtained in
height. For example, if you measured an average of 0.012 in.
(0.305 mm) for a tip with a slice height of 0.010 in. (0.254 mm), press the Up button until 0.0120
(0.305) is displayed within the Material Thickness field.
Figure 5-17:
Z Offset Adjustment
English units
G.
If a Z offset adjustment is required you will need to rebuild the calibration part. To do so:
After entering your adjustment value(s), press the Next button within the Adjust XYZ Calibration
screen.
The Select Option screen will be displayed; press the XYZ Tip Offset Calibration button within
this screen.
Note: Do not press the X (Cancel) button as this will close the wizard. If you
closed the wizard before properly calibrating your printer's tips, see
Offset Calibration" on page 192
process. You cannot build parts on the printer until the printer's tips are
calibrated.
The Prepare for Calibration screen will be displayed (see
on the screen making sure to install a build sheet, and then press the Next button.
Within the Select Calibration Part Location screen (see
location on the build sheet and then press the Next button.
step C
if this value is greater than the tip's slice
Up button for
adjusting Z
offset
for instructions on completing the calibration
step
159
Metric units
"XYZ Tip
step
14). Perform the steps indicated
16) select the calibration part's