C.
Within the Adjust XYZ Calibration page, slide the scale icons on the screen to match where
the support toolpath is most centered between the alignment indicators. The Delta X and
Delta Y fields will reflect adjustments made.
Note: Only one offset value can be selected for each axis, (i.e., an adjustment of
+X = 2 (0.002 in. (0.05mm)) and -X = 4 (-0.004 in. (0.1 mm)) is not allowed).
To be within tolerance, the X and Y values found on the calibration part must be
at or under 2 or 0.002 in. (0.05 mm). Therefore any reading within the range of 0
to 2 (0 to 0.05mm) for an axis is acceptable, although a reading of 0 is
preferable.
•
If the support toolpath is most centered at 2 (0.05mm) or less (as in
the printer is calibrated for that axis and an adjustment is not required. The following figure shows
an XY offset requiring no adjustments. If the support toolpath for your calibration part is most
centered at 2 (0.05mm) or less for both the X and Y axis, proceed to
Figure 6-14:
XY Offset - No Adjustment
English units
Scale icon
(slides up
and down)
Scale icon
(slides left and right)
203
Figure 6-10
and
Figure
step
9.
Metric units
6-12),