7.
Remove the model side flicker/brush assembly by lifting it upward until it clears it locating pins.
8.
Repeat
step 7
to remove the support side flicker/brush assembly.
Note: If the head is positioned above the purge area it may impede your ability
to remove the flicker/brush assemblies. Open the top cover and manually move
the head backwards and away from the purge area.
Figure 7-28:
Flicker/Brush Assembly Removal
9.
Clean and inspect the surface around the locating pins. Make sure that the purge ledges and
flicker/brush assemblies can sit flush on the surface.
10.
Inspect the purge ledges. Purge surfaces should be free from irregularities and excessive
material buildup.
Clean the purge ledges if they are to be reinstalled.
Replace the purge ledge(s) if excessive buildup has accumulated on the ledge's surface.
Replacement purge ledges are supplied within the Welcome Kit. Once these replacements are
depleted you will need to order additional replacement purge ledges.
234