Icon State
Flashing Red
MATERIAL STATUS ICONS
The two Material Status Icons within the page represent the model and support canisters installed/inserted in
the printer. Each icon displays the associated material's canister bay (M or S), the name of the material currently
installed in that bay (e.g. ABS-M30), and the current volume of material in that canister (e.g. 83.4 in
3
cm
). The Material Status Icons can appear in the following states (color usage, highlighting, and descriptions
apply to both icons):
Table 4-11:
Material Status Icons - Icon States
Icon State
Blue (no white
highlighted border)
Description
Valid tip, tip size, current odometer, and approximate tip life for this tip
is displayed.
Tip is within 10% of or has reached the odometer limit for the
associated material (see
life information).
Printer is still able to build with this tip, but you will be warned before
starting a build that the tip's odometer limit has been reached and part
quality may be negatively affected. User action is required to replace
tip. See
"Changing Tips or Material Type" on page 128
Yellow
Invalid tip/mismatch with currently loaded material, or tip has exceeded
the odometer limit for the associated material and no further parts can
be started.
See
"Tip Compatibility & Selection" on page 41
compatibility information and
page 128
Description
Valid canister inserted into bay, material name and current volume
displayed.
Material from canister is not loaded to the head. See
the Liquefier Tips" on page 118
Table 3-4 on page 42
"Changing Tips or Material Type" on
for instructions on changing tips.
for instructions.
70
for approximate tip
for instructions.
for material and tip
"Loading Material to