If the support toolpath is not centered at 2 (0.05mm) or less (as in
Figure
0.004 in. (0.1 mm). The +X scale icon has been moved downward to the 4 (0.1) and the Delta X
value reflects this adjustment (0.0040 in./0.100mm).
Figure 6-15:
Scale
icon
set to
4
D.
If an adjustment value for either axis is required you will need to rebuild the calibration part.
To do so:
•
After entering your adjustment value(s) press the Next button within the Adjust XYZ Calibration
page. Your calibration adjustment(s) will be saved.
•
The Select Option page will be displayed (see
button within this page.
Note: Do not press the X (Cancel) button as this will close the wizard.
If you closed the wizard before properly calibrating your printer's tips:
- Press the XYZ Tip Offset Calibration button within the Calibration page to
reopen the wizard (see
- Ensure that only the "Build Calibration Part" option is selected within the Tip to
Tip Calibration page (see
"Perform Z Tip-to-Tip Calibration" option is also selected, a new Z Tip-to-Tip
Calibration will be initiated, and the correction values entered previously will be
reset.
- Proceed with the wizard starting from
6-13) an offset adjustment is needed. The following figure shows a +X adjustment of 4 or
XY Offset - +X Adjustment
English units
step
Figure
Scale
icon
set to
.1
Figure
2).
6-3) and then press the Next button. If the
step
4.
204
Figure 6-11
Metric units
6-19); press the XYZ Tip Offset Calibration
and