Stratasys K6 Series User Manual page 209

3d production system
Table of Contents

Advertisement

B.
Determine where on each axis the support toolpath is most centered between the X-Y
alignment indicators (see
Figure 6-13
for Metric units). The numbers on the calibration part represent thousandths of
an inch (e.g., 4 = 0.004 in.).
Note: A calibration part printed using Nylon 12CF material will appear slightly
different than other materials, but calibration functionality is the same.
Figure 6-10:
Calibration Part - No Adjustment Needed (English units)
Magnified single side of a calibration part with a reading of 0.
Support
toolpath
Figure 6-11:
Calibration Part - Adjustment Needed (English units)
Figure 6-10
or
Figure 6-11
Most
centered
at 0
Alignment
indicators
200
for English units, and
Calibration Part
Figure 6-12
and

Advertisement